Vue de la page 0
UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATER
ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational pro-
cedures. For assistance or additional
information consult a qualified installer,
service agency, or the gas supplier.
VFN18MV,
VFN24MV
VFN30MV
Variable Manually-
Controlled
LO
PILOT
OFF
HI
EMBER MASTER
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation
section on page 4 of this manual.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design-
certified for these installations in accor-
dance with ANS Z21.11.2. Exceptions:
Do not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - NATURAL GAS LOG HEATER

UNVENTED (VENT-FREE)NATURAL GAS LOG HEATERALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCEOWNER’S OPERATION AND INSTALLATION MANUALSave this man

Page 2 - INFORMATION

10105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERINSTALLATIONContinuedINSTALLING HEATER BASEASSEMBLY WARNING: You must secur

Page 3

11105070OWNERS MANUAL10. Attach mounting brackets to fireplacefloor using masonry screws (in hard-ware package).11. Reattach heater base to mountingb

Page 4 - VENTILATION

12105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATER WARNING: Never use an openflame to check for a leak. Apply amixture of liq

Page 5

13105070OWNERS MANUALINSTALLATIONContinued WARNING: Failure to posi-tion the parts in accordance withthese diagrams or failure to useonly parts spe

Page 6

14105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERFigure 22 - PilotThermocoupleIgnitor ElectrodePilot Burner4. Wait five (5)

Page 7

15105070OWNERS MANUALTO TURN OFF GASTO APPLIANCE WARNING: Do not operateheater between locked positions. CAUTION: Do not try to ad-just heating l

Page 8

16105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERSPECIFICATIONS18" Variable 24" Variable 30" VariableManually

Page 9

17105070OWNERS MANUALTROUBLESHOOTINGNote: All troubleshooting items are listed inorder of operation. WARNING: Turn off and un-plug heater and let c

Page 10 - INSTALLATION

18105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATEROBSERVED PROBLEMOne or both burners do not light after ODS/pilot is litDela

Page 11 - OWNERS MANUAL

19105070OWNERS MANUALTROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to light any appliance.• Do not touch any e

Page 12

2105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATER1. This appliance is only for use with thetype of gas indicated on the ratin

Page 13

20105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERILLUSTRATEDPARTSBREAKDOWNVARIABLE MANUALLY-CONTROLLED MODELSVFN18MVVFN24MVV

Page 14 - OPERATING

21105070OWNERS MANUALPARTS LISTVARIABLE MANUALLY-CONTROLLED MODELSVFN18MVVFN24MVVFN30MVThis list contains replaceable parts used in your heater. When

Page 15

22105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERNote: Use only original replacement parts.This will protect your warranty c

Page 16 - MAINTENANCE

23105070OWNERS MANUALNOTES___________________________________________________________________________________________________________________________

Page 17

LIMITED WARRANTYVENT-FREE NATURAL GAS LOG HEATERSDESA International warrants this product to be free from defects in materials and components for one

Page 18 - TROUBLESHOOTING

3105070OWNERS MANUALPRODUCTIDENTIFICATIONFigure 1 - Ember MasterLeft Front LogControl KnobRear LogBase AssemblyFrontBurnerPiezoIgnitorRearBurnerCross

Page 19

4105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERConfined and Unconfined SpaceThe National Fuel Gas Code, ANS Z223.1defines a

Page 20 - BREAKDOWN

5105070OWNERS MANUALDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this work sheet to determ

Page 21

6105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERAIR FORCOMBUSTION ANDVENTILATIONContinuedVENTILATION AIRVentilation Air From

Page 22 - 2 lb. bag)

7105070OWNERS MANUALMINIMUM FIREPLACECLEARANCE TO COMBUSTIBLEMATERIALSLog Size 18", 24", 30"Side Wall 16"Ceiling 42"Floor 5&

Page 23

8105070FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATERNoncombustible Requirements forMaterial Distance (A) Safe Installation12&quo

Page 24 - WARRANTY INFORMATION

9105070OWNERS MANUAL14"Min.Combustible Material Non-Combustible Material Figure 8 - Minimum Fireplace ClearancesIf Installed at Floor LevelHear

Commentaires sur ces manuels

Pas de commentaire